In short

Most vinyl installation guides want a wood subfloor that is rated, stiff, well fastened and dry: commonly 3/4-inch plywood on joists no wider than 16 inches on center, and no more than 12% moisture content.1 2 Particleboard is where the guides split. Some rule it out entirely; at least one accepts it if it is dry and fastened every 6 inches along the joists.3 4

Wood-frame construction is where a lot of commercial flooring actually goes down: apartments, senior living, hotels, mixed-use buildings above a podium. The subfloor in those buildings is usually oriented strand board or plywood, sometimes with an underlayment panel on top, and occasionally an old particleboard layer left over from a previous floor. Each behaves differently under rigid vinyl, and the installation guides treat them differently too.

The panels, briefly

Plywood is built from thin wood veneers glued together with alternating grain directions, which makes it strong and stable. Oriented strand board is made by compressing wood strands with adhesive resin. Wagner Meters, which makes wood moisture meters, describes OSB as less expensive than plywood but less stable and more prone to water damage.5 Particleboard is made from much smaller wood particles bonded together, and it is the panel installation guides most often exclude.

Close-up of oriented strand board showing large overlapping wood strands
FIG 01Close-up of oriented strand board, its large wood strands overlapping in every direction.Photo: Øyvind Holmstad, CC0, via Wikimedia Commons

What the guides accept

These are the wood subfloor requirements stated in six installation documents for vinyl and rigid-core flooring.

DocumentPanel and structureFastening, moisture and stiffness
Timeless DesignsMinimum 3/4 inch, joists 16 inches on center, such as APA underlayment grade plywood without voids and with a sanded faceAll loose boards firmly fastened1
FloorFolioAPA underlayment grade plywood, minimum 3/4 inch, sanded face, preferred; two layers bridging the joints as best practiceStaples every 4 to 6 inches in the field and every 2 to 3 inches along the seams; particleboard, chipboard, hardboard and lauan not suitable3
Elite Flooring, Välinge lockPlywood, OSB and particleboard can be acceptableMaximum 12% moisture content; secured every 6 inches along joists with nails or screws4
National Flooring ProductsPlywood or OSBNot over wood that tests above 12% moisture content; deflection no more than 1/4 inch in 6 feet, or 1/16 inch between joists2
Marquis, rigid vinyl plankJoists no wider than 16 inches on centerPlan plank joints so they do not fall on subfloor joints or seams6
EverStep, glue-down and clickAPA-rated subfloor grade, as warranted by the manufacturerPanel maker's own requirements apply7

The common ground is clear: a rated panel, stiff framing, tight fastening and dry wood. The disagreements are about particleboard, about whether one layer is enough, and about how tightly underlayment must be fastened. On a commercial job the specified flooring's guide decides each one.

Particleboard: the panel most often ruled out

FloorFolio's guide says plainly that particleboard, chipboard and tempered hardboard are not suitable to install its floor coverings over, and that lauan board is not considered a suitable underlayment.3 Elite takes a different view and lists particleboard alongside plywood and OSB as acceptable when it is dry, at no more than 12% moisture content, and secured every 6 inches along the joists.4

In practice, particleboard turns up most often as an old underlayment layer in renovations, glued and stapled under sheet vinyl or carpet. If the specified flooring rules it out, the fix is removal and a new underlayment panel, not a patch. If the specified flooring allows it, check the moisture content and the fastening before accepting it, because any panel edge that rises will telegraph through rigid planks as a ridge.

Block of particle board on a dark background showing its compressed wood-chip core
FIG 02A block of particleboard showing its compressed wood-chip core.Photo: Elke Wetzig (elya), CC BY-SA 3.0, via Wikimedia Commons

Moisture content: test the wood too

Two guides in the table set the same moisture limit for wood: 12% moisture content.4 2 A pin or pinless wood meter checks it in minutes. Read panels in several places, including near exterior walls, around plumbing, and over any crawl space. A wet subfloor will dry after the floor is installed, and as it dries it shrinks, opening panel seams that then show through the flooring.

Stiffness and fastening

Rigid planks need a floor that does not move under foot. National Flooring Products expresses this as a deflection limit: when walked on, the substrate must not deflect more than 1/4 inch in a 6-foot radius, or more than 1/16 inch between floor joists.2 Marquis and Timeless both name 16-inch joist spacing.6 1 Squeaks and soft spots are a fastening problem. Wagner notes that loose or missing screws or nails can make a subfloor creak and stop flooring from adhering correctly, and lists tightening loose fasteners among the standard repairs.5

Fastening an underlayment is its own specification. FloorFolio calls for staples every 4 to 6 inches in the field and every 2 to 3 inches along the seams, following the underlayment manufacturer's recommendations.3 Elite asks for the subfloor itself to be secured every 6 inches along the joists.4 Fastener heads must sit flush or below the surface; a proud nail head will print through.

Underside of an OSB subfloor carried on I-joists, with fiberglass insulation between them
FIG 03The underside of an OSB subfloor carried on I-joists, with fiberglass insulation between them.Photo: Wikideas1, CC0, via Wikimedia Commons

Seams and joints

Subfloor seams are where wood floors fail visibly. Panels shrink and swell at their edges first, and a seam that opens or rises shows through thin flooring as a straight line. Marquis advises planning the layout so plank joints do not land on top of subfloor joints or seams.6 FloorFolio's best practice of two plywood layers, with the top layer bridging the joints of the bottom, addresses the same problem from below.3 For what to do when seams have already telegraphed, see why subfloor seams show through LVP.

Before accepting a wood subfloor

  • Identify the panel type and grade, and check it against the specified flooring's guide.
  • Check moisture content in several places against the product limit.
  • Walk the floor for deflection and squeaks, and refasten where needed.
  • Check flatness, with special attention to panel seams.
  • Look below if you can: crawl space conditions decide whether the wood stays dry.
Timber floor platform sheathed with wood panels on a joist frame, tools lying on its surface
FIG 04A timber floor platform decked with wood panels on a joist frame, tools lying on the surface.Photo: Trougnouf (Benoit Brummer), CC BY 4.0, via Wikimedia Commons

Sources

  1. Timeless Designs, “Click Floating Luxury Vinyl Installation Instructions”. timelessdesignsflooring.com/wp-content/uploads/2023/05/TD-Rigid-Core-Ins
  2. NFP, “Architect’s Choice LVP Installation Guide”. my-nfp.com/resource/architects-choice-lvp-installation-guide
  3. FloorFolio, “Installation Guide 2025”. floorfolio.com/wp-content/uploads/2025/FloorFolio-Installation-Guide-202
  4. Elite Flooring, “Välinge Installation Guide (Woodlands)”. eliteflooringusa.com/links/install-instructions/Elite-Installation-Guide
  5. Wagner Meters, “Subfloor Preparation for Flawless Flooring Installation”. wagnermeters.com/moisture-meters/wood-info/subfloor-preparation/
  6. Marquis Industries, “Rigid Vinyl Plank Installation Instructions (Angle)”. marquisind.com/static/resources/Angle_Angle%20Installation%20Instruction
  7. EverStep Flooring, “LVP Glue Down Installation Guidelines”. everstepflooring.com/technical/lvp-glue-down-installation-instructions/

General information for the flooring trade. This article was drafted with AI assistance and checked against the sources listed above; the manufacturer's current instructions and the project specification govern any real job. If something here is wrong or out of date, tell us.